Title: กำลังรับน้ำหนักบรรทุกของเสาเข็มเจาะแห้งในกรุงเทพฯ
Other Titles: CAPACITY OF DRY-PROCESS BORED PILES IN BANGKOK
Authors: ชัชวาลย์ พูนลาภพานิช
พลวิท บัวศรี
Keywords: น้ำหนักบรรทุก
เสาเข็ม
เจาะแห้ง
Bored piles
Dry process
Foundation
Pile capacity
Pile foundation
Static pile load test
Issue Date: 27-May-2555
Abstract: This paper presents the comparison of dry-process bored pile capacities from static pile load test with the allowable pile capacities calculated from the friction resistance specified by Bangkok Building Codes. The study estimates the ultimate pile capacities using Mazurkiewicz’s method based on 42 static pile load test data of bored piles 0.50 and 0.60 m. diameters which were constructed in central Bangkok area. The comparison indicates that the average factor of safety is 2.26 and the minimum factor of safety is 1.7. The percentage of piles which have factor of safety below 2.0 is 17. This paper also presents a reduction factor equation for estimating the allowable capacity of dry-process bored piles having 19-25 m. pile length.
URI: http://dspace.spu.ac.th/handle/123456789/3596
Appears in Collections:EGI-03. บทความวิชาการ/วิจัย (อื่นๆ)