A Study on the System Imbalance of the Single-Switch Converter for the Conductive Common Mode Noise Reduction

dc.contributor.authorBoonpirom Nimiten_US
dc.date.accessioned2555-08-05T04:58:32Z
dc.date.available2555-08-05T04:58:32Z
dc.date.issued2555-08-05T04:58:32Z
dc.description.abstractThis paper reduces system imbalance by replacing the single-switch converter with a synchronized double-switch converter based on two active switches technique and hybrid balance technique, including active balance and passive balance for common mode noise reduction. The system balance is experimentally evaluated by the common mode rejection ratio (CMRR). Finally, examples show that the CMRR of the single-switch converter is improved from 1.67 dB to 32.04 dB when the double-converter with two active switches technique is applied and to 41.5 dB when the double-switch converter with hybrid balance technique is applied.en_US
dc.description.sponsorshipมหาวิทยาลัยศรีปทุมen_US
dc.identifier.urihttps://dspace.spu.ac.th/handle/123456789/3784
dc.language.isootheren_US
dc.relation.ispartofseriesVol.E90-B No.8 pp.2126-2137Vol.E90-B No.8 pp.2126-2137en_US
dc.subjectconductive common mode noiseen_US
dc.subjectdouble-switch converteren_US
dc.titleA Study on the System Imbalance of the Single-Switch Converter for the Conductive Common Mode Noise Reductionen_US
dc.typeArticleen_US

ไฟล์

ชุดต้นฉบับ
ตอนนี้กำลังแสดง1 - 1 ของ 1
กำลังโหลด...
รูปภาพขนาดย่อ
ชื่อ:
IEICE SEARCH SYSTEM.pdf
ขนาด:
56.3 KB
รูปแบบ:
Adobe Portable Document Format
มัดใบอนุญาต
ตอนนี้กำลังแสดง1 - 1 ของ 1
ไม่มีรูปขนาดย่อ
ชื่อ:
license.txt
ขนาด:
1.73 KB
รูปแบบ:
Item-specific license agreed upon to submission
คำอธิบาย: